- High-precision measurement
- High corrosion resistance
- Strong electronic circuit protection
- Integrated automotive connector
- Immunity to external magnetic fields
Eurosens Direct advantages for installers:
- Special free diagnostic software
- Software function of flow direction reverse
- Smart software processing of fuel flow pulses allows to avoid use of check valves. It mimimize hydraulic resistance of system and very important factor.
- High quality of measuring chambers
- Warranty term – 3 years, without limitation of passed flow.
- You can use specially designed Deaerator device to remove air from fuel system.
Connecting thread |
M14x1, 5 |
Max pressure |
2.5 MPa |
Power voltage, V |
10 – 50 |
Reverse polarity protection |
Yes |
Measuring accuracy |
±1% |
Temperature range,°C |
-40 – +85 |
Maximum flow rate in l/h |
500 |
Output interface |
pulses, RS232, RS485, K-Line, CAN |
Seal rating |
IP 67 |
Digit index means maximum fuel rate in each measuring chamber. It is a main parameter to choose suitable flow meter. Simpliest version of flow meter has P index. Due to high quality of measuring chambers P-serie provide enough precision even without microcontroller circuit.
Flow meter modification |
Q start liters/hour |
Q min liters/hour |
Q nom liters/hour |
Q max liters/hour |
pulses/liter |
Error of measurement |
Direct P100 |
0,5 |
2 |
50 |
100 |
96…102 |
± 2% |
Direct P250 |
0,5 |
5 |
125 |
250 |
96…102 |
± 2% |
Direct P500 |
1,0 |
10 |
250 |
500 |
48…52 |
± 2% |
Q start – flow rate when fuel meter starts to measure Q min , Q max – Min and Max flow rate for range with declared precision In Direct PH flow meters Hall-sensors are used instead of reed switch. That provide protection from external magnetic field.
Direct PH100 |
0,5 |
2 |
50 |
100 |
96…102 |
± 2% |
Direct PH250 |
0,5 |
5 |
125 |
250 |
96…102 |
± 2% |
Direct PH500 |
1,0 |
10 |
250 |
500 |
48…52 |
± 2% |
PN – fuel flow meter has powerful STM32 processor inside. PN flowmeters have some advantages over P-serie: 1. Calibration table is not used for compromised coefficient calculation but recorded in non-volatile memory of flow meter. And calibration coefficients are applied in real-time. So, PN-flow meter always have same weight of pulse (normalized output). Also precision of measurement is better (1% error instead of 2%). 2. Instead of reed switches – Hall effect sensors are used. 3. Sensor can detect external intervention in operation and store this fact in memory 4. PN meter can provide not only fuel consumption but some other parameters : operation time of diesel, fuel consumption in different operation modes (idle, normal load, overload, external intervention) and time of operation in these modes. This information is available via RS232/RS485 interface – Direct PN(RS), or via K-line in Direct PN. 5. Temperature sensor and temperature compensation. 6. No need in check valve, because of smart processing of fuel vibration and software flow direction autodetection.
Direct PN100 |
0,5 |
1 |
50 |
100 |
200 |
± 1% |
Direct PN250 |
0,5 |
2 |
125 |
250 |
100 |
± 1% |
Direct PN500 |
1,0 |
5 |
250 |
500 |
50 |
± 1% |
Flow meters with improved precision have extra index .05
Direct PN100.05 |
0,5 |
1 |
50 |
100 |
200 |
± 0.5% |
Direct PN250.05 |
0,5 |
2 |
125 |
250 |
100 |
± 0,5% |
Direct PN500.05 |
1,0 |
5 |
250 |
500 |
50 |
± 0.5% |
Fuel meters can have built-in display. It is marked by index I.
Direct PN I counters list |
|
Direct PN100I |
0,5 |
1 |
50 |
100 |
200 |
± 1% |
Direct PN250I |
0,5 |
2 |
125 |
250 |
100 |
± 1% |
Direct PN500I |
1,0 |
5 |
250 |
500 |
50 |
± 1% |
Flow meters with display and improved precision
Direct PN100.05I |
0,5 |
1 |
50 |
100 |
200 |
± 0.5% |
Direct PN250.05I |
0,5 |
2 |
125 |
250 |
100 |
± 0,5% |
Direct PN500.05I |
1,0 |
5 |
250 |
500 |
50 |
± 0.5% |
We have a modification with only index I with build-in display. These meters have external supply, but don’t have pulse output or any other interface. It is stand-alone fuel counter with display, built-in microcontroller and Hall-sensors.
Direct 100I |
0,5 |
1 |
50 |
100 |
200 |
± 1% |
Direct 250I |
0,5 |
2 |
125 |
250 |
100 |
± 1% |
Direct 500I |
1,0 |
5 |
250 |
500 |
50 |
± 1% |
Flow meter modification with display without pulse output but with built-in longlife power battery have index A. It is stand-alone autonomous fuel counter. For power economy reed switches are used instead of Hall sensors. Due to low power consumption these meters can operate 3 years without battery replacement.
Direct A100I |
0,5 |
1 |
50 |
100 |
200 |
± 2% |
Direct A250I |
0,5 |
2 |
125 |
250 |
100 |
± 2% |
Direct A500I |
1,0 |
5 |
250 |
500 |
50 |
± 2% |
Flow meter modifications with build-in battery, display, pulse output and external power. Hall-sensors and STM32 microcontroller are used.
Direct PN A100I |
0,5 |
1 |
50 |
100 |
200 |
± 1% |
Direct PN A250I |
0,5 |
2 |
125 |
250 |
100 |
± 1% |
Direct PN A500I |
1,0 |
5 |
250 |
500 |
50 |
± 1% |
Every version of fuel meter can be manufactured in copper version Direct RS – Fuel flow meters with serial RS232 and RS485 onboard. Communication is performed via “Delta RS” protocol or MODBUS.
Direct RS 100 |
0,5 |
1 |
50 |
100 |
None |
± 1% |
Direct RS 250 |
0,5 |
2 |
125 |
250 |
None |
± 1% |
Direct RS 500 |
1,0 |
5 |
250 |
500 |
None |
± 1% |
And version with display
Direct RS 100I |
0,5 |
1 |
50 |
100 |
None |
± 1% |
Direct RS 250I |
0,5 |
2 |
125 |
250 |
None |
± 1% |
Direct RS 500I |
1,0 |
5 |
250 |
500 |
None |
± 1% |
Direct CAN – fuel flow meters with a CAN bus interface. Standard protocol SAE J1939 is supported.
Direct CAN 100 |
0,5 |
1 |
50 |
100 |
None |
± 1% |
Direct CAN 250 |
0,5 |
2 |
125 |
250 |
None |
± 1% |
Direct CAN 500 |
1,0 |
5 |
250 |
500 |
None |
± 1% |
And version with display
Direct CAN 100I |
0,5 |
1 |
50 |
100 |
None |
± 1% |
Direct CAN 250I |
0,5 |
2 |
125 |
250 |
None |
± 1% |
Direct CAN 500I |
1,0 |
5 |
250 |
500 |
None |
± 1% |
Flyers
Fuel flow meters Direct |
|
Fuel flow meters Direct CAN |
|
Direct PN I counters list |
|
Direct PN counter modes |
|
Fuel flow meters from Mechatronics |
|
Certificates
Certificate of Customs Union Technical Regulations 018/2011 |
|
EMC declaration – Customs Union Technical Regulations 020/2011 |
|
Eurosens certificate (E-mark) |
|
River register certificate |
|
For installation
Direct, Delta installation manual |
|
Eurosens configurator |
|
Configuration manual |
|
Eurosens Direct PN firmware v.2.3 |
|
Eurosens Direct RS firmware v.1.8 |
|
Direct PN A I passport |
|
Direct I passport |
|
Direct A I passport |
|
Direct CAN passport |
|
Eurosens Delta RS protocol |
|
Eurosens Delta MODBUS protocol |
|
Eurosens Direct/Delta CAN messages |
|
For developers : Eurosens Direct 3D CAD drawings
Eurosens Direct IGS file |
|
Eurosens Direct STEP file |
|