{"id":9374,"date":"2019-01-12T12:35:23","date_gmt":"2019-01-12T09:35:23","guid":{"rendered":"http:\/\/mechatronics.by\/?page_id=9374"},"modified":"2021-02-28T10:13:56","modified_gmt":"2021-02-28T07:13:56","slug":"eurosens-datalink","status":"publish","type":"page","link":"https:\/\/mechatronics.by\/es\/products\/data-interfaces\/eurosens-datalink\/","title":{"rendered":"Puente de radio Eurosens Datalink"},"content":{"rendered":"<p> <\/p>\n<p><br \/>\n<strong>Radio extendedor de la l\u00ednea RS485.<\/strong><br \/>\nConsiste en un par de dispositivos y forma un enlace de comunicaci\u00f3n de radio de dos v\u00edas entre 2 redes RS485. Se puede utilizar en lugar de cable en la red RS485. La aplicaci\u00f3n t\u00edpica es la transmisi\u00f3n de datos desde el sensor del remolque al rastreador de GPS instalado en el cami\u00f3n. En ese caso, un transmisor est\u00e1 conectado al rastreador de GPS mediante la l\u00ednea RS485. El segundo transmisor est\u00e1 conectado a la l\u00ednea RS485 de los sensores del remolque. Ambos transmisores deben ser alimentados por fuentes de voltaje locales.<\/p>\n<p>Tenga en cuenta que el enlace de radio agrega alg\u00fan retraso en la mensajer\u00eda. Si el rastreador de GPS realiza solicitudes a la l\u00ednea RS485 y espera respuesta, la respuesta llegar\u00e1 durante 200 ms. Por lo tanto, el rastreador de GPS debe tener un valor de tiempo de espera para la comunicaci\u00f3n RS485 no inferior a 200 ms.<\/p>\n<p>Los transmisores se env\u00edan emparejados, ambos transmisores emparejados tienen el mismo n\u00famero de serie. Los transmisores con diferentes n\u00fameros de serie no funcionar\u00e1n.<br \/>\n&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td><a href=\"\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R.jpg\"><img loading=\"lazy\" class=\"alignleft wp-image-9370 size-medium\" src=\"\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R-272x300.jpg\" alt=\"Wireless temperature sensor\" width=\"272\" height=\"300\" srcset=\"https:\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R-272x300.jpg 272w, https:\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R-930x1024.jpg 930w, https:\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R.jpg 1673w\" sizes=\"(max-width: 272px) 100vw, 272px\" \/><\/a><\/td>\n<\/tr>\n<tr>\n<td><strong>Receptor &#8211; Datos t\u00e9cnicos<\/strong><br \/>\nTensi\u00f3n de alimentaci\u00f3n, V 5-30<br \/>\nConsumo m\u00e1ximo de corriente, mA 25<br \/>\nRango de temperatura, \u00b0 C -40 &#8230; + 85<br \/>\nInterfaz RS485<br \/>\nN\u00famero de transmisores hasta\u00a02<br \/>\nDimensiones, mm 100x90x60<br \/>\nPeso, g 200<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><\/p>\n<p><br \/>\n<br \/>\n<\/p>","protected":false},"excerpt":{"rendered":"<p>Radio extendedor de la l\u00ednea RS485. Consiste en un par de dispositivos y forma un enlace de comunicaci\u00f3n de radio de dos v\u00edas entre 2 redes RS485. Se puede utilizar en lugar de cable en la red RS485. La aplicaci\u00f3n t\u00edpica es la transmisi\u00f3n de datos desde el sensor del remolque al rastreador de GPS [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":11557,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"side-navigation.php","meta":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v16.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Eurosens Datalink RF bridge<\/title>\n<meta name=\"description\" content=\"Consists from pair of devices and forms two-way radio communication link between 2 RS485 networks. Can be used instead of cable in the RS485 network.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Eurosens Datalink RF bridge\" \/>\n<meta property=\"og:description\" content=\"Consists from pair of devices and forms two-way radio communication link between 2 RS485 networks. Can be used instead of cable in the RS485 network.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/\" \/>\n<meta property=\"og:site_name\" content=\"Mechatronics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/EurosensDelta\" \/>\n<meta property=\"article:modified_time\" content=\"2021-02-28T07:13:56+00:00\" \/>\n<meta property=\"og:image\" content=\"\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R-272x300.jpg\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/mechatronics.by\/#website\",\"url\":\"https:\/\/mechatronics.by\/\",\"name\":\"Mechatronics\",\"description\":\"\\u041a\\u043e\\u043d\\u0442\\u0440\\u043e\\u043b\\u044c \\u0440\\u0430\\u0441\\u0445\\u043e\\u0434\\u0430 \\u0442\\u043e\\u043f\\u043b\\u0438\\u0432\\u0430 \\u0438 \\u0434\\u0440\\u0443\\u0433\\u0438\\u0445 \\u043f\\u0430\\u0440\\u0430\\u043c\\u0435\\u0442\\u0440\\u043e\\u0432 \\u0440\\u0430\\u0431\\u043e\\u0442\\u044b \\u043c\\u0430\\u0448\\u0438\\u043d\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/mechatronics.by\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/#primaryimage\",\"inLanguage\":\"es\",\"url\":\"\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R-272x300.jpg\",\"contentUrl\":\"\/\/mechatronics.by\/wp-content\/uploads\/2018\/03\/DTS-RF-R-272x300.jpg\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/#webpage\",\"url\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/\",\"name\":\"Eurosens Datalink RF bridge\",\"isPartOf\":{\"@id\":\"https:\/\/mechatronics.by\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/#primaryimage\"},\"datePublished\":\"2019-01-12T09:35:23+00:00\",\"dateModified\":\"2021-02-28T07:13:56+00:00\",\"description\":\"Consists from pair of devices and forms two-way radio communication link between 2 RS485 networks. Can be used instead of cable in the RS485 network.\",\"breadcrumb\":{\"@id\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mechatronics.by\/\",\"url\":\"https:\/\/mechatronics.by\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mechatronics.by\/products\/\",\"url\":\"https:\/\/mechatronics.by\/products\/\",\"name\":\"\\u041f\\u0440\\u043e\\u0434\\u0443\\u043a\\u0442\\u044b\"}},{\"@type\":\"ListItem\",\"position\":3,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/\",\"url\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/\",\"name\":\"\\u0418\\u043d\\u0442\\u0435\\u0440\\u0444\\u0435\\u0439\\u0441\\u044b \\u0438 \\u043f\\u0435\\u0440\\u0435\\u0434\\u0430\\u0447\\u0430 \\u0434\\u0430\\u043d\\u043d\\u044b\\u0445\"}},{\"@type\":\"ListItem\",\"position\":4,\"item\":{\"@id\":\"https:\/\/mechatronics.by\/products\/data-interfaces\/eurosens-datalink\/#webpage\"}}]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","_links":{"self":[{"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/pages\/9374"}],"collection":[{"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/comments?post=9374"}],"version-history":[{"count":5,"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/pages\/9374\/revisions"}],"predecessor-version":[{"id":9376,"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/pages\/9374\/revisions\/9376"}],"up":[{"embeddable":true,"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/pages\/11557"}],"wp:attachment":[{"href":"https:\/\/mechatronics.by\/es\/wp-json\/wp\/v2\/media?parent=9374"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}