Eurosens LPS is designed to detect the presence of fuel residues in the discharge lines of the gasoline tanker. Installed behind the drain valve. Transmits fuel presence status “Yes/No” via RS485 interface (LLS protocol).
It can be used in conjunction with other Eurosens sensors to monitor gas tanker operation and deliver petroleum products.
The Eurosens LPS is a capacitive sensor designed as a spacer between the standard API flange of a gasoline tanker and the drain valve.
Specification:
| Power voltage, V | 9– 32 |
| Max current consumption (12V), mA | 40 |
| Temperature range, °C | -40 – +85 |
| Output interface | RS-485 |
| Putput protocols | LLS |
| Protection class | IP 67 |
Sensors supports LLS data protocol. Compatible with popular GPS tracking devices with RS485 interface.
| Eurosens LPS flyer | |
| Eurosens LPS specification | |
| Eurosens LPS manual |
![]() |
![]() |