Install

Permalink Gallery

Display-Delta

Display-Delta

Connection Eurosens Delta flowmeters to the fuel indicator Eurosens Display F1.

Permalink Gallery

Display-Dominator

,

Display-Dominator

,

Connection level sensors Eurosens Dominator to the fuel indicator Eurosens Display F1.

Permalink Gallery

Eurosens Delta install scheme 1

Eurosens Delta install scheme 1

Installation Eurosens Delta (all modifications) on sucction side.
Designations on the scheme:
1 – backpressure valve
2 – additional filter of thin cleaning
3 – pressuure valve

Permalink Gallery

Cutting the Eurosens Dominator sensor

Cutting the Eurosens Dominator sensor

Cutting of electrodes at installation. Designations on the scheme: 1 – fuel tank 2 – fuel h2 – possible dirt or water L – initial length L1 – the recommended cutting length When installing the bottom stop, the distance from the bottom end of the electrodes to the bottom of the tank should be approximately 30 mm. In the absence of a bottom stop: 10-15mm. When the bottom stop is installed, the sensor should protrude beyond the upper plane of the tank by about 15 mm after immersion in the tank . In the absence of the bottom stop, the sensor should be completely lowered onto the bayonet plate without touching the bottom of the tank.